Artikel Alle Rechte vorbehalten
referiert
Veröffentlicht

Comparative research of two kinds of flat fan nozzle atomization process

Zugehörigkeit
College of Science, China Agricultural University, Beijing 100193, China
Xie, Chen;
Zugehörigkeit
College of Science, China Agricultural University, Beijing 100193, China
He, Xiongkui;
Zugehörigkeit
College of Science, China Agricultural University, Beijing 100193, China
Song, Jianli;
GND
1058938843
Zugehörigkeit
Julius Kühn Institute (JKI), Institute for Application Techniques in Plant Protection, Germany
Herbst, Andreas

The objectives of this research were to study the atomization characteristics of normal flat fan nozzles and air induction flat fan nozzles which were made by the LECHLER Company by a particle droplet image analysis system (PDIA) with visualized features. Images of ST110-03 and IDK120-03 nozzles’spraying fan from orifice to 30 mm below nozzle were taken at 0.3 MPa to observe the structure of the spraying fan. Spraying visualizations were conduct from 10 to 70 mm with the interval of 10 mm below the nozzle in the spraying fan centerline of ST110-01, 02, 03, 04 and IDK120-01, 02, 03, 04 at 0.3 MPa to analyze the influence of orifice width on spraying sheet length. To research the influence of spraying pressure on liquid sheet length and droplet size, spraying visualizations were performed from 10 to 70mm with the interval 10mm below the nozzle in the spraying fan centerline of ST110-03 and IDK120-03 at 0.2, 0.3, 0.4, 0.5, 0.6 MPa. The results showed that there was a larger liquid sheet in the ST110-03 spraying fan. It was very easy to observe the wave formation and irregular atomization holes in the ST110-03 spraying fan. There was a smaller spraying sheet in the IDK120-03 spraying fan than in the ST110-03. There were many bubbles in the spraying sheet of the IDK120-03. The data showed that the spraying sheet length of the ST110-03 was increased from 20 to 40 mm and the atomization length of the IDK120-03 was increased from 10 to 20 mm, and also resulted in increasing intensity of bubbles with the orifice width increasing. The liquid sheet length of the ST110-03 was decreased from 35 to 22 mm and the droplets volume mean diameter was decreased from 128.2 to 92.4 μm. Also, the wave’s amplitude was increased by increasing the spray pressure. The liquid sheet-atomization length of the IDK120-03 was decreased from 40 to 30 mm and the droplets volume mean diameter was decreased from 366.4 to 285.3 μm with increased spray pressure. The conclusion of the research was that there are huge differences between the spraying sheet and atomization region of IDK and ST nozzles. The air bubble existed in the liquid sheet of the IDK, and the liquid sheet length showed negative correlation with the droplets volume mean diameter.

Dateien

Zitieren

Zitierform:
Zitierform konnte nicht geladen werden.

Zugriffsstatistik

Gesamt:
Volltextzugriffe:
Metadatenansicht:
12 Monate:
Volltextzugriffe:
Metadatenansicht:

Rechte

Nutzung und Vervielfältigung:
Alle Rechte vorbehalten