Artikel CC BY 4.0
referiert
Veröffentlicht

Measurement of trace elements in murine liver tissue samples : Comparison between ICP-MS/MS and TXRF

Zugehörigkeit
Department of Nutritional Physiology, Institute of Nutritional Sciences, Friedrich Schiller University Jena, Jena, Germany
Lossow, Kristina;
ORCID
0000-0002-8641-5738
Zugehörigkeit
Department of Nutritional Physiology, Institute of Nutritional Sciences, Friedrich Schiller University Jena, Jena, Germany
Schlörmann, Wiebke;
Zugehörigkeit
TraceAge-DFG Research Unit on Interactions of Essential Trace Elements in Healthy and Diseased Elderly, Potsdam-Berlin-Jena, Germany
Tuchtenhagen, Max;
Zugehörigkeit
Department of Nutritional Physiology, Institute of Nutritional Sciences, Friedrich Schiller University Jena, Jena, Germany
Schwarz, Maria;
ORCID
0000-0002-4873-7488
Zugehörigkeit
TraceAge-DFG Research Unit on Interactions of Essential Trace Elements in Healthy and Diseased Elderly, Potsdam-Berlin-Jena, Germany
Schwerdtle, Tanja;
ORCID
0000-0002-3307-1038
Zugehörigkeit
Department of Nutritional Physiology, Institute of Nutritional Sciences, Friedrich Schiller University Jena, Jena, Germany
Kipp, Anna Patricia

Background Trace elements exhibit essential functions in many physiological processes. Thus, for research focusing on trace element homeostasis and metabolism analytical methods allowing for multi-element analyses are fundamental. Small sample amounts may be a big challenge in trace element analyses especially if also other end points want to be addressed in the same sample. Therefore, the aim of the present study was to examine trace elements (iron, copper, zinc, and selenium) in murine liver tissue prepared by a RIPA buffer-based lyses method. Methods and results After centrifugation, lysates and pellets were obtained and trace elements were analyzed with TXRF in liver lysates. The results were compared to that obtained by a standard microwave-assisted acidic digestion with subsequent ICP-MS/MS analysis of the same liver tissue, liver lysates, and remaining pellets. In addition, trace element concentrations, determined in murine serum with both methods, were compared. For serum samples, both TXRF and ICP-MS/MS provide similar and highly correlating results. Furthermore, in liver lysate samples prepared with RIPA buffer, comparable trace element concentrations were measured by TXRF as with the standard digestion technique and ICP-MS/MS. Only marginal amounts of trace elements were detected in the pellets. Conclusion Taken together, the results obtained by the present study indicate that the RIPA buffer-based method is suitable for sample preparation for trace element analyses via TXRF, at least for the here investigated murine liver samples.

Zitieren

Zitierform:
Zitierform konnte nicht geladen werden.

Zugriffsstatistik

Gesamt:
Volltextzugriffe:
Metadatenansicht:
12 Monate:
Volltextzugriffe:
Metadatenansicht:

Rechte

Nutzung und Vervielfältigung: